1. Check whether the pipeline valves are unobstructed and closed, and whether the equipment is normal.
2. Turn on the induced draft fan and the combustion-supporting fan to ensure ventilation in the kiln. Check and test.
3. Test whether the igniter is normal, listen and see, there is no abnormality, first fire and then gas ignition.
4. When heating up, air first and then air, and when cooling down, air first and then air. Observe air, air flow, and flame conditions in the kiln, and adjust in time.
5. It is necessary to ensure three stability: stable wind, stable gas, stable kiln speed, and stable feeding volume. Observe and contact.
6. to achieve three diligence: diligent observation, diligent analysis, diligent adjustment. Watch the brightness and material changes in the kiln and adjust it in time.
7. According to the production process requirements, adjust the temperature in the kiln, observe the temperature in the kiln, and add and subtract air volume and air volume.
8. When positive pressure and other emergencies occur at the kiln head, the quick-cut valve should be closed in time.
9. Regularly inspect each equipment pipeline, valve and instrument.
10. Make a record of shift handover and introduce the situation to the shift.